Differential Pressure (DP) Transmitter for Flow and Level

Photo: Raimond Spekking · CC BY-SA 4.0 · Image credits

Instrumentation & Sensors

Differential Pressure (DP) Transmitter for Flow and Level

Model: DP-200

DP transmitter with 0.1 % accuracy for orifice flow, tank level and filter pressure-drop measurement.

  • 0–0.1 bar to 16 bar ranges
  • Built-in square-root extraction for flow
  • One-sided overpressure resistant
  • Optional 3-valve manifold

Nationwide delivery · Free technical advice

Measuring range0 – 0.1 … 16 bar (DP)
Accuracy±0.1 % FS
Output4–20 mA · HART
Turndown ratio100 : 1

Overview

The DP-200 measures the pressure difference between two points and can apply square-root extraction to compute flow from an orifice or venturi. The sensor tolerates up to 400 bar one-sided overpressure, and a 3-valve manifold is optional.

Technical specifications

General

Measuring range
0 – 0.1 … 16 bar (DP)
Accuracy
±0.1 % FS
Output
4–20 mA · HART
Turndown ratio
100 : 1

Materials & construction

Material
AISI 316L · Hastelloy (opt.)
Process connection
¼″ NPT · 7/16″-20 UNF

Process conditions

Operating temperature
−40 … +120 °C
Protection
IP66 / IP67

Electrical

Supply
10.5 – 42 V DC

Applications

Orifice and pitot flow measurement
Closed-tank level
Filter and strainer pressure drop
Air handlers and duct monitoring

Need help selecting or pricing?

Our engineers recommend the right model for your process conditions and quote price and lead time.

Talk to us on Telegram
Ask me